Request More Information


alpha Personal Network

A new electronic personal monitoring and alarm system can also be enhanced with telemetric capability.

alphaSCOUT

The alphaSCOUT personal monitor and alarm is the central element of the optional alpha personal network. Since it is wireless and completely detached from the SCBA, the alphaSCOUT is always at hand. It receives pressure information from the transmitter on the back plate and then calculates the remaining service time. A motion detector and alarm signal are also integrated.

In addition to the shortrange signal transfer with the backplate transmitter alphaMITTER, it can communicate with an incident command base station by using a separate long-range signal. This gives it full telemetric capability. An evacuation signal can also be sent to operation teams or the entire crew. In shielded environments a second alphaSCOUT works as a repeater so that the signal can be extended even further.

alphaHUD

Head-Up-Display alphaHUD, which is easily attached to the inside of a Ultra Elite mask. It provides pressure status, alarm information on low battery, pressure and evacuation at the edge of field of vision – hands free.

In order to ensure a constant, non-distracting readability the LEDs glow for two seconds and then gradually dim for eight seconds before glowing again. They adjust automatically to ambient lighting conditions. A blinking alarm signal called “buddy light” is also visible externally when air pressure drops to a dangerous level.

alphaMITTER

The alphaMITTER, a short-range transmitter on the SCBA back plate sends air pressure data to the alphaSCOUT or alphaHUD every two seconds.

alphaBASE

alphaBASE is the standard receiver which works in combination with any PC. An external aerial with magnetic foot can optionally be used for vehicle mounted applications.

A battery-powered version of the alphaBASE as well as the alphaBASE standard can be used with the xplore TABLET PC.

alphaTAG writer

Each user can identify himself with the alphaSCOUT he is using through the alphaTAG identification tag. Individual alphaTAGs are programmed by the alphaTAG writer, using a convenient PC software module.

alphaCONTROL 2

MSA’s own and unique alphaCONTROL 2 monitoring software runs automatically without operator intervention. Complete incident data is automatically logged and analysed. Even without telemetry, the alphaCONTROL 2 software can as well be used as a substitute for conventional tally boards.

ALTAIR 5X

Used in conjunction with the alpha Personal Network, the ALTAIR 5X with W-USB option can monitor operative personnel using breathing apparatus and portable gas detection equipment while sending information to alphaBASE. All gas readings and alarms can be seen by incident command monitoring personnel in real time.


Markets: Fire Service, Chemical, General Industrial, Government, Police / Military, Oil & Gas
Applications: Firefighting, Civil Disturbances, Search & Rescue, Toxic Detection, Homeland Security, Confined Space
Standard
10058211

alphaMITTER for SCBA - AirMaXX/AirGo

10058212

alphaSCOUT TM with telemetry module

10058214

alphaBASE, receiver box + PC-software

10065873

alphaTAG (set of 5)

10065875

alphaTAG writer EU

10068805

Tablet PC (xplore)

10069803

alphaMITTER for BD96 SL (Q)

10070795

alphaBASE (battery powered), EU

10076041

Tablet PC Xplore alphaBASE(bat.po)EU

10086118

alphaHUD

alphaMITTER

  • Directive 94/9/EC (ATEX):
    • BVS 05 ATEX E 149
    • II 1G Ex ia IIC T3/T4 Ga
    • EN 60079-0:2012; EN60079-11:2012; EN 60079-26:2007
  • Battery: -20°C≤ Tamb≤+50°C
    • T4 - Durcell Plus Power MN1500, Duracell Industrial AA LR6
    • T3 - Varta 4706 Max Tech
  • IECEx Directive:
    • IECEx BVS 06.0010: Ex ia IIC T3/T4 Ga
    • IEC 60079-0:2011; IEC 60079-11:2011; IEC 60079-26:2006
  • Directive 1999/5/EC (R&TTE):
    • EN 300 440-1, EN 301 489-1/-3, EN 50371, CE 0681
  • Directive 93/68/EC
    • (Low Voltage) : EN 60950
  • Directive 89/336/EC (EMC):
    • EN 61 000-6-2, EN 61 000-6-3, CE 0158, EN 137
  • Other:
    • Australia AS/NZS 4268
    • SAR Test to ARPANSA RPS3
    • AS/NZS CISPR 22
    • C-Tick

alphaSCOUT

  • Directive 94/9/EC (ATEX):
    • BVS 05 ATEX E 14
    • II 1G Ex ia IIC T3/T4 Ga
    • EN 60079-0:2012; EN60079-11:2012
  • Battery: -20°C≤ Tamb≤+50°C
    • T4 - Durcell Plus Power MN1500, Duracell Industrial AA LR6
    • T3 - Varta 4706 Max Tech
  • IECEx Directive:
    • IECEx BVS 06.0010: Ex ia IIC T3/T4 Ga
    • IEC 60079-0:2011; IEC 60079-11:2011; IEC 60079-26:2006
  • Directive 1999/5/EC (R&TTE):
    • EN 300 440-1, EN 301 489-1/-3, EN 50371, CE 0681
  • Directive 93/68/EC
    • (Low Voltage) : EN 60950
  • Directive 89/336/EC (EMC):
    • EN 61 000-6-2, EN 61 000-6-3, CE 0158, EN 137
  • Other:
    • Australia AS/NZS 4268
    • SAR Test to ARPANSA RPS3
    • AS/NZS CISPR 22
    • C-Tick

alphaHUD

  • Directive 94/9/EC (ATEX):
    • BVS 07 ATEX E085
    • II 1G Ex ia IIC T4 Ga
    • EN 50 014, EN 50 020, EN 50 284
  • Battery: --20 °C ≤ Ta ≤ +60 °C
    • Panasonic Photo Power CR2 Lithium
    • Varta Professional 6206 CR2 Lithium
    • Duracell Ultra M3 CR2 Lithium
  • Directive1999/5/EC(R&TTE):
    • EN300440-1, EN301489-1/-3, CE0681
  • Directive 93/68/EC (Low Voltage):
    • EN 60950 Directive 89/336/EC (EMC) : EN 61 000-6-2, EN 61 000-6-3, 0158, EN 136