Gas- und Brandmeldeanlagen

Feuer- und Gaserkennungssystem der Zero Two-Reihe

Modulares System mit der umfangreichsten Palette von Steuerkarten für integrierte Feuer- und/oder Gaserkennungssysteme. Das System der Reihe Zero Two eignet sich zur Überwachung beliebiger Kombinationen aus: brennbaren Gasen, H2S, toxischen Gasen, Ultraschall, Sauerstoffmangel und Flammen. Außerdem ermöglicht die offene Architektur dem System die Aufnahme anderer Sensorgeräte, etwa für Rauch- und Hitzeerkennung, sowie manueller Meldestellen. 

TA102A Single Channel Combustible Trip Amplifier Module

The TA102A is a single-channel Combustible Gas Trip Amplifier Module designed for use with one General Monitors intelligent transmitter to monitor combustible gases and vapors within the lower explosive limit (LEL) and provide status indication and alarm outputs. Microprocessor-based electronics allow all options to be user selectable through a front panel interface (mode / select switch and digital display). A digital display indicates fault codes and set up options. Other features include: LED indications of status, as well as both open collector and relay outputs for fault, low alarm and high alarm.

Zero Two-Steuermodul zur Anwendung mit brennbaren Gasen 4802A

Das 4802A ist ein für die Verwendung mit unseren bewährten katalytischen Sensoren bestimmtes Einkanal-Steuermodul für brennbare Gase. Es ist zur Überwachung brennbarer Gase und Dämpfe unterhalb der unteren Explosionsgrenze (UEG) und zur Ausgabe von Statusanzeigen und Alarmen vorgesehen. Die mikroprozessorgesteuerte Elektronik erlaubt dem Benutzer die Auswahl aller Optionen über ein Bedienfeld an der Vorderseite. Ein digitales Display zeigt Gaskonzentration, Fehlercodes, Kalibrierhinweise und Einstelloptionen an. Weitere Funktionen: LED-Statusanzeigen und offene Collector- und Relais-Ausgänge.

TA202A Single Channel H2S Trip Amplifier Module

The TA202A is a single-channel H2S Trip Amplifier Module for use with our H2S Intelligent Sensors. It is designed to monitor H2S in parts per million (ppm) levels and provide status indication and alarm outputs. Microprocessor-based electronics allow all options to be user selectable through front panel interface (mode / select switch and digital display).

2602A Zero Two Series Control Module for H2S Applications

The 2602A is a single-channel H2S Control Module that has been designed to monitor H2S in parts per million (ppm) levels and provide status indication and alarm outputs. Microprocessor-based electronics allow all options to be user selectable through front panel interface (mode / select switch and digital display). The digital display on the 2602A indicates hydrogen sulfide gas concentration, fault codes, calibration cues and setup options. Other features include LED indications of status, relay outputs for fault, low alarm and high alarm, and serial communications ports.

TA402A Single Channel Trip Amplifier

The Model TA402A is a single-channel trip amplifier module designed for use with the FL3100 Series Flame Detectors, providing status indication and alarm outputs.

FL802 Multi-Channel Flame Detection Readout / Relay Display Module

The Model FL802 is a compact, reliable and versatile multi-channel flame detection readout/relay display module designed to monitor up to eight remote FL4000H or FL3100 Series detectors.

TA502A Single Channel Trip Amplifier Module

The TA502A is a single-channel generic trip amplifier designed for use in Zero Two Series Gas and Flame Detection Systems. It is used to process the 0-22 mA signal from any field mounted transmitter.

CC02A Serial Communications Module

The CC02A Communications Card facilitates serial communications between each module in a Zero Two Series Flame and Gas Detection System and an external host computer, which allows fast access to operational and setup data registers. It supports a Burst Read feature that returns all registers of a module in a single transmission.

FM002A Facilities Module

The FM002A is a facilities module that provides a range of common facilities for all Zero Two control modules housed in the chassis. The FM002A is plugged into the last slot on the right-hand side of the Zero Two chassis. It may be daisy-chained allowing one FM002A to serve up to 100 Zero Two modules in any combination.

IN042 Four Zone Control Module

The IN042 is a four zone input module designed for use with two-wire field devices such as smoke or heat detectors, pull switches and manual callpoints. It is designed to monitor these devices and provide both status indication and fault / alarm outputs for each zone.

MD002 Monitored Driver Output Module

The MD002 is a monitored driver output module designed for four independent outputs requiring monitoring in their non-active state, such as extinguishing solenoids, beacons, horns, etc. Each driver is independent and has circuitry to monitor short and open circuits in field wiring.

ZN002A Three Zone Control Module

The ZN002A is a Zone Control Module for the Zero Two Series Fire and Gas Detection System. The ZN002A provides zoning and voting functions for three separate and independent zones of gas and / or flame detection.