Request More Information


ALTAIR® 2X Gas Detector

 All ALTAIR 2X Gas Detectors

  • Incorporate proven XCell® sensor technology
  • Enhance worker safety, compliance and traceability
  • Minimize cost of ownership
  • Demonstrate rugged durability
 
Product Options
  • ALTAIR 2XP Gas Detector with XCell Pulse Technology: H2S  -
    • Features the first stand-alone bump test, which eliminates the need for bottled gas!
    • Bump test anytime, anywhere
    • Based on proven science and patented sensor capabilities
  • ALTAIR 2XP Gas Detector with XCell Pulse Technology: H2S
  • ALTAIR 2X Gas Detectors: CO, CO-HC (High Concentration), CO-H2 (Hydrogen Resistant), H2S-LC, SO2, NO2, NH3 and Cl2
  • ALTAIR 2XT Two-Tox Gas Detector: CO/H2S, CO-H2/H2S, CO/H2S-LC, CO/NO2 and SO2/H2S-LC

Low cost of ownership

  • Fastest sensor response times, lowest calibration gas flow rate on the market
  • > 4-year expected sensor life
  • 3-year warranty on instrument & most sensors (2 years on Cl2, NH3)
  • Stand-alone bump tests reduce maintenance, increase productivity (ALTAIR 2XP only)
  • 1 device can monitor 2 gases (ALTAIR 2XT only)

Increased safety awareness & real-time compliance

  • Stand-alone bump test anytime, anywhere without specific calibration gas (ALTAIR 2XP only)
  • Bump pass: green LED flash every 15s, large on-screen checkmark
  • Bump fail or expiration: red LED flash every 15s, no checkmark
  • End-of-sensor-life warning and alarm

Full-time traceability

  • Records 75 alarm events
  • 150+ hours of periodic data (ALTAIR 2X and 2XP)
  • 100+ hours of periodic data (ALTAIR 2XT)
  • Compatible with MSA GALAXY® GX2 Automated Test System and MSA Link Pro software

Rugged durability

  • Tough over-molded rubber armor
  • Survives multiple 25-ft drops onto concrete
  • Agency-certified dust- and water-tight IP67 construction
  • Intrinsically-safe design

 

Related Resources


Markets: Contractor, Fire Service, Industrial, Oil & Gas, Utilities
Applications: Confined Space, Toxic Detection

  • ALTAIR 2XP Gas Detector with XCell Pulse Technology: H2S
  • ALTAIR 2X Gas Detectors: CO, H2S-LC and SO2
  • ALTAIR 2XT Two-Tox Gas Detector: CO/H2S and SO2/H2S-LC
  • Available in charcoal gray and glow-in-the-dark housing.
  • Contact MSA for alternate or custom setpoints.

Standard
10153984

ALTAIR 2X H2S-Pulse [10,15], charcoal

10153986

ALTAIR 2X CO [CO: 25, 100], charcoal

10154040

ALTAIR 2XT CO/H2S [CO: 25, 100: H2S: 10, 15], charcoal

10154071

Detector, ALTAIR 2XT, CO-H2/H2S, Gray

10154181

ALTAIR 2XT CO/H2S [CO: 25, 100; H₂S: 10, 15], glow-in-the-dark

10154182

Detector, ALTAIR 2XT, CO-H2/H2S, Glow

10154185

ALTAIR 2X CO [CO: 25, 100], glow-in-the-dark

10154187

Detector, ALTAIR 2X, CO-HC, Glow

10154188

ALTAIR 2X H2S-Pulse [10,15], glow-in-the-dark

10154189

Detector, ALTAIR 2X, H2S-LC, Glow

10154190

Detector, ALTAIR 2XT, SO2/H2S-LC, Glow

10154191

Detector, ALTAIR 2X, SO2, Glow

10157955

ALTAIR 2X H2S-Pulse [5,10,10,5], charcoal

10157956

ALTAIR 2X H2S-Pulse [5,10,10,5], glow-in-the-dark

10157957

Detector,ALTAIR 2XT,CO/H2S,GY(H2S:5,10)

10157958

Detector,ALTAIR 2XT,CO/H2S,Glo(H2S:5,10)

10157959

ALTAIR 2XT,CO/H2S,GY(CO:50,200/H2S:5,10)

10157960

ALTAIR 2XT,CO/H2S,Glo,CO:50,200/H2S:5,10

10157961

ALTAIR 2XT,CO/H2S,GY(CO:30,200/H2S:5,10)

10157962

ALTAIR 2XT,CO/H2S,Glo,CO:30,200/H2S:5,10

10157963

ALTAIR 2XT,CO/H2S,GY(CO:35,100/H2S:5,10)

10157964

ALTAIR 2XT,CO/H2S,Glo,CO:35,100/H2S:5,10

10157965

ALTAIR 2X CO [CO: 30, 60, 60, 30], charcoal

10157966

ALTAIR 2X CO [CO: 30, 60, 60, 30], glow-in-the-dark

10157967

ALTAIR 2X CO [CO: 50, 200, 200, 50], charcoal

10157968

ALTAIR 2X CO [CO: 50, 200, 200, 50], glow-in-the-dark

10157969

ALTAIR 2X CO [CO: 30, 200, 200, 30], charcoal

10157970

ALTAIR 2X CO [CO: 30, 200, 200, 30], glow-in-the-dark

10157971

ALTAIR 2X CO [CO: 35, 100, 100, 35], charcoal

10157972

Detector, ALTAIR 2X, CO, Glow (35,100)

10157973

ALTAIR 2X, H2S-LC, Gray (5,10,10,1.6)

10157974

ALTAIR 2X, H2S-LC, Glow (5,10,10,1.6)

10157975

Detector, ALTAIR 2X, SO2, Gray (1,2,1,1)

10157976

Detector, ALTAIR 2X, SO2, Glow (1,2,1,1)

10159579

ALTAIR 2XT,CO/H2S,GY(CO:25,100/H2S:5,10)

10159580

ALTAIR 2XT,CO/H2S,Glo,CO:25,100/H2S:5,10

10159651

ALTAIR 2XT,SO2/H2SLC,GY,SO2:1,2/H2S:5,10

10159652

ALTAIR2XT,SO2/H2SLC,Glo,SO2:1,2/H2S:5,10

10160798

Detector, ALTAIR 2X, CO-HC, GY (200,300)

10160799

Detector, ALTAIR 2X, CO-HC, Glo(200,300)

10160805

ALTAIR2XT,SO2/H2SLC,Glo,SO2:1,2/H2S:5,10

10162887

Detector, ALTAIR 2X, CO-H2, GY (50,200)

10162888

Detector, ALTAIR 2X, CO-H2, Glo (50,200)

  • USA/Canada
    • cCSAus Class I Div 1 Groups A, B, C, D
    • Class II Div 1 Groups E, F, G Class III
    • Tamb = -40C to +60C T4
    • USA: UL 913 7th Edition
    • Canada: CSA 22.2 No. 157
  • ATEX: FTZU II 2G Ex ia IIC T4 Gb -40C to +60C
  • IEC/Australia/New Zealand: FTZU Ex ia IIC T4 Gb   -40C to +60C